|
Recent Publications
2003
2002
2001
If you
need paper copies of any of the following reports, please
contact the ACD Webmaster by telephone at 301-975-3108,
by facsimile at 301-926-8671, by email at acd_webmaster@nist.gov,
or by mail at NIST, 100 Bureau Drive, Stop 8390, Gaithersburg,
MD 20899-8390.
The
free Adobe Acrobat Reader must be installed (http://www.adobe.com)
to view the files.
2003
- Brazhnik, K.P., Vreeland, W.N., Howell, P.B., Kishore, R., Wells,
J., Helmerson, K., and Locascio, L.E., “Manipulating Self-Assembled
Nanotubes,” Micro Total Analysis Systems 2003 Editor(s): M. Allen
Northrup, Klavs Jensen, D.J. Harrison, 689-692 (2003).
- Choquette, S.J., Blackburn, D.H., Etz, E.S., and Hurst, W.S.,
“Relative Intensity Correction Standards for Raman Spectroscopy for
Excitation with Several Common Laser Wavelengths,” Amer. Pharm. Rev.,
6(2), 74-80 (2003).
- Choquette S.J., O'Neal L.E., and Duewer, D.L., "Rare-Earth
Glass Reference Materials for Near Infrared Spectrometry:
Absorption Band Temperature Dependencies," Anal Chem
2003;75(4):961-966. (Preprint
PDF file)
- Duewer, D.L., Choquette, S.J., O'Neal, L., and Filliben, J.J.,
"Rare Earth Glass Reference Materials for Near Infrared Spectrometry:
Sources of X-Axis Location Variability," Anal. Chim. Acta, 490(1-2),
85-98 (2003). (Preprint
PDF file)
- Etz, E.E., Choquette, S.J., and Hurst, W., “Development and Certification
of NIST Standard Reference Materials for Relative Raman Intensity Calibration,”
European Microbeam Analysis Society, Proceedings, In: 8th Workshop on Modern
Developments and Applications in Microbeam Analysis, Cadiz, Spain. EMAS-2003,
89-103 (2003).
- Kulin, S., Kishore, R., Helmerson, K., and Locascio, L.E., “Optical
Manipulation of Liposomes as Microreactors,” Langmuir, 19(20); 8206-8210, (2003).
- MacCrehan, W.A., Layman, M.J., and Secl, J.D., “Hair Combing to Collect
Organic Gunshot Residues (OGSR),” For. Sci. Intl., 135(2), 167-173 (2003).
- Reyes, D.R, Perruccio, E., Becerra, S.P., Locascio, L.E., and Gaitan, M.,
“Patterning Retinal Cells on Polyelectrolyte Multilayers,” Micro Total Analysis
Systems 2003, ed(s): M. Allen Northrup, Klavs Jensen, D.J. Harrison, 713-716, (2003).
- Ross, D. J. and Locascio, L. E., “Effect of Caged Fluorescent Dye on the
Electroosmotic Mobility in Microchannels,” Anal. Chem., 75(5), 1218-1220 (2003).
- John C. Travis, Melody V. Smith,
David L. Duewer, "Report of the Results of
SIM.QM-P6:UV/Visible Spectrophotometry Wavelength Standard
Interlaboratory Comparison", NISTIR 6961 (2003). (Preprint PDF file)
- Vreeland, W.N. and Locascio, L.E., “Nature’s Packaging: Using Bio-Inspired
Liposomes for Rapid, High Efficiency Mixing in Microfluidic Systems,” MicroTotal
Analysis Systems 2003, ed(s): M. Allen Northrup, Klavs Jensen, D.J. Harrison, 37-40 (2003).
2002
- Bedner, M., MacCrehan, W.A., and Helz, G.R., "Improving
the Recoveries of Unstable N-Chloramines Determined by
Liquid Chromatography-Postcolumn Electrochemical Detection,"
J. Chrom. Sci. 40(8), 447-455 (2002).
- Becker, H. and Locascio, L.E. "Polymer Microfluidic
Devices: A Review," Talanta; 56, 267-287, (2002).
- Henry, A.C., Waddell, E., Shreiner, R., and Locascio,
L.E., "Control of Electroosmotic Flow in Laser Ablated
and Chemically Modified Hot Imprinted Polymer Microchannels,"
Electrophoresis, 23(5), 791-798, (2002).
- Henry, A.C., Ross, D.L., and Locascio, L.E., “Moleculary Imprinted
Stationary Phases for Plastic Microchip-Based Capillary Electrochromatography,”
MicroTotal Analysis Systems 2002 Editor(s) Yoshinobu Baba, Shuichi Shoji,
Albert van den Berg, 434-436 (2002).
- Johnson, T.J., Ross, D., and Locascio L.E., "Rapid
Microfluidic Mixer," Anal. Chem., 74(1), 4551,
(2002).
- Johnson, T.J. and Locascio, L.E., "Characterization
and Optimization of Slanted Well Designs for Microfluidic
Mixing under Electroosmotic Flow," Lab-on-a-Chip,
2(3), 135-140, (2002).
- Kline, M.C, Duewer, D.L, Redman, J.W., Butler, J.M.,
"PCR Amplification of DNA from Aged Blood Stains:
Quantitative Evaluation of the Suitability for Purpose"
of Four Filter-Papers as Archival Media. Anal Chem 2002;74(8):1863-1869.
(Preprint PDF file)
- Kramer, G.W., Ruehl, M.A., and Schäfer, R., "SpectroML:
An Extensible Markup Language for the Interchange of Molecular
Spectrometry Data," NISTIR 6821, (2002).
- Kramer, G.W., "Automation & Robotics in Genomics
Laboratories," Book Chapter 10 in Genomic Technologies
Present and Future, Eds: Galas-McCormick, 313-343, 2002.
- Locascio, L.E., Hong, J., and Gaitan, M., "Liposomes
as Signal Amplification Reagents for Assays in Microfluid
Channels," Electrophoresis, 23(5), 799-804, (2002).
- MacCrehan, W.A., Bedner, M., and Helz, G.R., “Greener Chlorine
Wastewater Disinfection Using Alternative Dechlorination Agents,”
In: Proceedings of the 6th Annual Green Chemistry and Engineering
Conference, American Chemical Society, 48-53 (2002).
- MacCrehan, W.A., Reardon, M.R., Duewer, D.L., "A
Quantitative Comparison of Smokeless Powder Measurements,"
J. Forensic Sci. 2002;47(6):1283-1287.
- MacCrehan, W.A. and Reardon, M.R., "A Qualitative
Comparison of Smokeless Powder Measurements," J.
Forensic Sci., 47(5), 997-1001, (2002).
- MacCrehan, W.A., Secl, J.D., and Duewer, D.L., "Graphical
Evaluation of Smokeless Powder Association Using Computer-Intensive
Statistics," J. Forensic Sci., 2002 (submitted).
- MacCrehan, W.A., Reardon, M.R., Duewer, D.L., "Associating
Gunpowder and Residues from Ccommercial Ammunition using
Compositional Analysis with the Propellant to Stabilizer
Ratio (P/S)," J. Forensic Sci., 2002;47(2):260-266.
- Margolis, S.A., Vangel, M., Duewer, D.L., "Certification
of SRM 970, Ascorbic Acid in Serum, and the Analysis of
Associated Interlaboratory Bias in the Measurement Process,"
Clin. Chem., 2003;49:463-469.
- Pugmire, D.L., Waddell, E.A., Haasch, R., Tarlov, M.J.,
and Locascio, L.E., "Surface Characterization of
Laser Ablated Polymers Used for Microfluidics," Anal.
Chem., 74, 871-878, (2002).
- Ross, D. and Locascio, L.E., "Microfluidic Temperature
Gradient Focusing," Anal. Chem., 74(11), 2556-2564,
(2002).
- Ross, D., Olsen, K.G., and Locascio, L.E., "Electrokinetic
Sample Dilution in Microfluidics," Anal. Chem., 2002
(submitted).
- Ross, D.J. and Locascio, L.E., "Microfluidic Temperature
Gradient Focusing," MicroTas 2002 Conference Proceedings,
2002 (submitted).
- Travis,
J.C., and Duewer, D.L., "Holmium Oxide Solution as a Prototype
Intrinsic Standard in Molecular Absorption Spectrophotometry,"
Fourth Oxford Conference on Spectrometry,
Art Springsteen, Michael Pointer, Editors, Proc. SPIE 4826, 113-122
(2002). (Preprint
PDF file)
- Travis, J.C., Zwinkels, J.C., Mercader, F., Ruiz, A.,
Early, E.A., Smith, M.V., Noel, M., Maley, M., Kramer,
G.W., Eckerle, K.L., and Duewer, D.L., "An International
Evaluation of Holmium Oxide Solution Reference Materials
for Wavelength Calibration in Molecular Absorption Spectrometry,"
Anal. Chem., 74, 3408-3415 (2002). (Preprint
PDF file)
- Waddell, E.A., Locascio, L.E., and Kramer, G.W., "UV
Laser Micromachining of Polymers for Microfluidic Applications,"
JALA, 7(1), 63-67, (2002).
2001
- Choquette, S.J., Travis, J.C., Zhu, C., Duewer, D.L.,
"Wavenumber Standards for Near Infrared Spectrometry",
Book Chapter in Handbook of Vibrational Spectroscopy,
John Chalmers and Peter R. Griffiths, eds; Wiley, UK,
2001. (Preprint PDF file)
- Choquette, S.J., Travis, J.C., O'Neal, L.E., Zhu, C.,
and Duewer, D.L., "SRM® 2035: A rare earth oxide
glass for the wavelength calibration of near infrared
dispersive and Fourier transform spectrometers,"
Spectrosc., 16(4), 14-19, 2001.
- DeRose, P.C., Travis, J.C., Smith, M.V., Pugmire, D.L.,
Small, J.A., and Kramer, G.W., "Distinguishing Acceptable
and Unacceptable Cr Thin Films for SRM 2031 Metal-on-Quartz
Filters," J.Res., NIST
- Duewer, D.L., Kline, M.C., Redman, J.W., Newall, P.J.,
Reeder, D.J., "NIST Mixed Stain Studies #1 and #2:
Interlaboratory Comparison of DNA Quantification Practice
and Short Tandem Repeat Multiplex Performance with Multiple-Source
Samples," J. Forensic Sci. 2001;46(5):1199-1210.
(Preprint PDF file)
- Esch, M.B., Locascio, L.E., Tarlov, M.J., Baumner,
A., and Durst, R.A., "Detection of Viable Cryptosporidium
parvum using DNA Probes and Liposomes in a Microfluidic
Chip," Anal. Chem., 73(13); 2952-2958 (2001).
- Gao, J., Xu, J., Locascio, L.E., and Lee, C.S., "Integrated
Microfluidic System Enabling Protein Digestion, Peptide
Separation, and Protein Identification," Anal. Chem.,
73(11), 2648-2655 (2001).
- Jiang, Y., Wang, P-C, Locascio, L.E., and Lee, C.S.,
"Integrated Plastic Microfluidic Deviceswith ESI-MS
for High Throughput Drug Screening and Residue Analysis,"
Anal.Chem., 73(9), 2048-2053 (2001).
- Johnson, T.J., Waddell, E.A., Kramer, G.W., and Locascio,
L.E., "Chemical Mapping of Hot Embossed and UV Laser
Ablated Microchannels in Poly(Methyl Methacrylate) Using
Carboxylate Specific Fluorescent Probes," Appl. Surf.
Sci., 2001 (in press).
- Johnson, T.J., Ross, D., Gaitan, M., and Locascio,
L.E., "Laser Modification of Preformed Polymer Microchannels:
Application To Reduce Band Broadening around Turns Subject
to Electrokinetic Flow," Anal. Chem., 73(15), 3656-3661
(2001).
- Kramer, G.W., Ruehl, M.A., and Schäfer, R., "SpectroML
A Markup Language for Molecular Spectrometry Data,"
J. of the Assoc. for Lab Automation, 6(6), 76-82, (2001).
- MacCrehan, W.A., Patierno, E.R., Duewer, D.L., Reardon,
M.R., "Investigating the Effect of Changing Ammunition
on the Composition of Organic Additives in Gunshot Residue
(OGSR)," J. Forensic Sci. 2001;46(1):57-62.
- Reardon, M.R. and MacCrehan, W.A., "Developing
a Quantitative Extraction Technique for Determining the
Organic Additives in Smokeless Handgun Powder," J.
Forensic Sci., 46(4), 802-807 (2001).
- Ross, D., Johnson, T.J., and Locascio, L.E., "Imaging
of Electro-Osmotic Flow in Plastic Microchannels,"
Anal. Chem., 73(11), 2509-2515 (2001).
- Ross, D., Gaitan, M., and Locascio, L.E., "Temperature
Measurement in Microfluidic Systems Using a Temperature-Dependent
Fluorescent Dye", Anal. Chem., 73(11), 2509-2515
(2001).
- Thomas, J.B., Kline, M.C., Gill, L.M., Yen, J.H., Duewer,
D.L., Sniegoski, L.T., Sharpless, K.S., "Preparation
and Value Assignment of Standard Reference Material 968c
Fat-Soluble Vitamins, Carotenoids, and Cholesterol in
Human Serum," Clin. Chim. Acta 2001;305:141-155.
- Wimmer, R.F., Waddell, E., Barker, S.L.R.B., Suggs,
A., Locascio, L.E., Love, B.J., and Love, N.G., "Development
of an Upset Early Warning Device to Predict Defloculation
Events," Proceedings of the Water Environment Federation
Conference and Exposition, (2001).
|