Fee Schedules (effective 1/18/07) for:

NIST Calibration Services

NIST Fee Schedule for ITS-90 Calibrations
       
Service ID#
fee, $
  Description of Services
 

   
33010C
11,223
  capsule SPRT (13.8 K to 30 °C)
33020C
11,223
  capsule SPRT (13.8 K to 157 °C)
33030C
12,193
  capsule SPRT (13.8 K to 232 °C)
33031C
8,708
  capsule SPRT (24.5 K to 30 °C)
33032C
9,095
  capsule SPRT (24.5 K to 157 °C)
33033C
10,065
  capsule SPRT (24.5 K to 232 °C)
33040C
7,782
  capsule SPRT (54 K to 30 °C)
33050C
8,171
  capsule SPRT (54 K to 157 °C)
33060S
10,110
  capsule SPRT (54 K to 232 °C)
33065S
at cost
  capsule SPRT (84 K to 0.01°C)
33070C
7,600
  capsule SPRT (84 K to 30 °C)
33080C
7,600
  capsule SPRT (84 K to 157°C)
33090C
9,543
  capsule SPRT (84 K to 232°C)

33100C

2,891
  capsule SPRT (0 °C to 30 °C)
33110C
3,375
  capsule SPRT (0 °C to 157 °C)
33120C
5,122
  capsule SPRT (0 °C to 232 °C)
33130C
5,295
  capsule SPRT (234 K to 30 °C)
33140C
11,844
  Rhodium-Iron or Platinum-Cobalt Resistance Thermometers (0.65 K to 24.6 K)
33141C
14,564
  Rhodium-Iron or Platinum-Cobalt Resistance Thermometers (0.65 K to 83.8 K)
33142C
13,393

n-Type Germanium Resistance Thermometers (0.65 K to 24.6 K)
33150C
3,820
  long stem SPRT (83 K to 0.01 °C)
33160C
4,499
  long stem SPRT (83 K to 30 °C)
33170C
5,178
  long stem SPRT (83 K to 157 °C)
33180C
5,857
  long stem SPRT (83 K to 232 °C)
33190C
6,922
  long stem SPRT (83 K to 420 °C)
33200C
7,989
  long stem SPRT (83 K to 661 °C)
33210C
3,162
  long stem SPRT (234 K to 30 °C)
33220C
4,131
  long stem SPRT (234 K to 157 °C)
33230C
5,005
  long stem SPRT (234 K to 232 °C)
33240C
5,975
  long stem SPRT (234 K to 420 °C)
33250C
7,333
  long stem SPRT (234 K to 661 °C)
33260C
1,533
  long stem SPRT (0 °C to 30 °C)
33270C
2,212
  long stem SPRT (0 °C to 157 °C)
33280C
2,890
  long stem SPRT (0 °C to 232 °C)
33290C
3,861
  long stem SPRT (0 °C to 420 °C)
33300C
5,122
  long stem SPRT (0 °C to 661 °C)
33310C
10,558
  long stem SPRT (0 °C to 962 °C)
33320C
114
  additional table at time of test
33330C
385
  additional table at later date
33340C
638
  minimum charge for unsuitable thermometer
33350S
at cost
  special test of resistance thermometer
33360S
at cost
  special test of thermometric fixed-point
33370M
23,976
  long stem SPRT (83 K to 420 °C)
33380M
26,740
  long stem SPRT (83 K to 661 °C)
       
Contacts:

>83.8 K: Greg Strouse, (301) 975-4803, gstrouse@nist.gov

>83.8 K: Mark Reeher, (301) 975-4821, mark.reeher@nist.gov

<84 K: Wes Tew, (301) 975-4811, wtew@nist.gov
fax: (301) 548-0206

Top of Page

NIST Fee Schedule for Industrial Thermometer Calibrations < 550 °C
     
NOTE: The minimum number of test points per thermometer is two. Fahrenheit ranges are not direct conversions of the Celsius ranges.    
     
Service ID# fee, $ Description of Services
     
    Liquid-in-Glass Thermometers
31010C 452/pt Laboratory Thermometers (0 ºC to 150 ºC) (32 ºF to 300 ºF)
31020C 555/pt Laboratory Thermometers (151 ºC to 315 ºC) (301 ºF to 600 ºF )
31030C 555/pt Laboratory Thermometers (316 ºC to 550 ºC) (601 ºF to 1022 ºF )
31040C 555/pt Laboratory Thermometers (-1 ºC to -110 ºC) (31 ºF to -166  ºF)
31050C 452/pt Laboratory Thermometers (Liquid N2) (-196 ºC or -321 º F)
31100C at cost Quantity Tests of Liquid-In-Glass Thermometers
     
    Resistance Thermometers
31110S 452/pt Special Tests of Industrial Platinum Resistance Thermometers, Thermistor Thermometers, Digital Thermometers and Other Types of Thermometers (0 ºC to 150 ºC) (32 ºF to 300 ºF )
31120S 555/pt Special Tests of Industrial Platinum Resistance Thermometers, Thermistor Thermometers, Digital Thermometers and Other Types of Thermometers (151 ºC to 315 ºC) (301 ºF to 600 ºF )
31130S 555/pt Special Tests of Industrial Platinum Resistance Thermometers, Thermistor Thermometers, Digital Thermometers and Other Types of Thermometers (316 ºC to 550 ºC) (601 ºF to 1022 ºF )
31140S 555/pt Special Tests of Industrial Platinum Resistance Thermometers, Thermistor Thermometers, Digital Thermometers and Other Types of Thermometers (-1 ºC to -110 ºC) (31 ºF to -166 ºF )
31150S 452/pt Special Tests of Industrial Platinum Resistance Thermometers, Thermistor Thermometers, Digital Thermometers and Other Types of Thermometers (Liquid N2) (-196 ºC or -321 ºF)
     
    Special Thermometers
31170S 1,768 Special Tests of Calorimetric Thermometers
31180S 1,829 Special Tests of Beckmann Thermometers
     
    Additional Services
31190S 392 Additional copy of Table from Results of 31110S-31150S at a Later Date
31200S 88 Preliminary Examination of Ineligible Thermometer
31250S 88 Additional Copy of Report
31260S at cost Special Thermometry Services, by Prearrangement
     
Contacts:   
Greg Strouse, (301) 975-4803, gstrouse@nist.gov   
Dawn Cross, (301) 975-4822, dawn.cross@nist.gov
fax: (301) 548-0206   

Top of Page

Thermocouples, Thermocouple Materials, and Thermometer Indicators
COMPARISON CALIBRATIONS, TEMPERATURE MEASURED WITH THERMOCOUPLE
 Service ID#   Fee, $  TC Type Temp Range ºC   Points Min. Length (mm)  Temp. °C Expanded Uncert., k=2, °C
               
32010C 1,199 S 0 to 1450 1 ºC or 1 °F Interv. Table 700 0 to 1100, 1450 0.3, 1.6
32020C 1,199 R 0 to 1450 1 ºC or 1 °F Interv. Table 700 0 to 1100, 1450 0.3, 1.6
32030C 1,803 B 0 to 1750 1 ºC or 1  °F Interv. Table 1000 0 to 800, 800 to 1100, 1450, 1750 (3 µV) 0.3, 1.6, 2.4
32031C 1,199 B 800 to 1750 1 ºC or 1 °F Interv. Table 1000 800 to 1100, 1450, 1750 0.6, 1.6, 2.4
32040C 1,199 E 0 to 1000 4 to 15 700 0 to 1000 0.9
32041C 1,199 J 0 to 760 4 to 15 700 0 to 760 0.7
32042C 1,199 K 0 to 1100 4 to 15 700 0 to 1100 1
32043C 1,199 N 0 to 1100 4 to 15 700 0 to 1100 1
32044C 1,199 T 0 to 400 4 to 15 700 0 to 400 0.4
32050C 556/pt
Comparison calibration, two point min., per point, for all items above
32060C 308
Each additional table of results at 1 °C or 1 °F intervals, for type S, R, or B at later date
32061C 184
Each additional table of results at 1 °C or 1 °F intervals, for type S, R, or B at time of test
32070C 1,199
Thermocouple materials tested against Pt Thermoelectric standard, 4 to 15 points, 700 mm min. lengths
 
CALIBRATION AT METAL FREEZING POINTS, MINIMUM TC WIRE DIAMETER 0.4 mm, FREEZING POINT DETERMINATION AT Au, Ag, Al, AND Zn
 Service ID#   Fee, $  TC Type Temp Range ºC   Points Min. Length (mm)  Temp. °C Expanded Uncert., k=2, °C
32090C 3,031 S or B 0 to 1450 1ºC or 1 °F Interv. Table and equations to generate table 1000 at freezing points 0 to 1100 1450 0.1 0.1 1.6
32091C 1,076 Type S or T, freezing point determination, per point, two point minimum     
 
CALIBRATION OF DIGITAL THERMOMETER INDICATOR OR PORTABLE POTENTIOMETER
 Service ID#   Fee, $  
32100C 911 Indicator or Potentiometer, first dial or range
32101C 507 Indicator or Potentiometer, each additional dial or range
 
COMPARISON CALIBRATION OF THERMOCOUPLES OR THERMOCOUPLE MATERIALS TESTED AGAINST Pt THERMOELECTRIC STANDARD, TEMPERATURE MEASURED WITH SPRT, MINIMUM TC WIRE LENGTH 1.0 M, TWO POINT MINIMUM
 Service ID#   Fee, $   
32110C
644/pt
Range -110 ºC to 315 ºC and Liquid N2 (-196 ºC) or -166 º F to 600 ºF and Liquid N2 (-321 ºF), Expanded Uncertainty 0.4º C
32120C
644/pt
316 ºC to 550 ºC or 60 ºF to 1022 ºF, Expanded Uncertainty 0.5 ºC     
 
Table at one degree intervals for Type T thermocouple for any of the following options: (The cost of the table will be in addition to the calibration per point covered under fee schedule services numbered 32110C-32120C.)
 Service ID#   Fee, $     
32141C
540
Option 1: Table from -196 ºC to +300 ºC (-321 ºF to +572 ºF), calibration points at (-196, -110, -50, +100, +200, +300) ºC
32142C
540
Option 2: Table from -196 ºC to +100 ºC (-321 ºF to +212 ºF), calibration points at (-196, -110, -50, +50, +100) ºC
32143C
540
Option 3: Table from -110 ºC to +300 ºC (-166 ºF to +572 ºF), calibration points at (-110, -50, +100, +200, +300) ºC
32144C
540
Option 4: Table from -110 ºC to +100 ºC (-166 ºF to +212 ºF), calibration points at (-110, -50, +50, +100) ºC
32145C
540
Option 5: Table from 0 ºC to 300 ºC (32 ºF to 572 ºF ), calibration points at (+100, +200, +300) ºC
32146C
540
Option 6: Table from -110 ºC to 0 ºC (-166 ºF to +32 º F), calibration points at (-110, -50) ºC
32147C
540
Option 7: Table from -196 ºC to 0 ºC (-321 ºF to +32 ºF), calibration points at (-196, -110, -50) °C
32150S
At Cost
Special Tests of Thermocouples and Thermocouple Materials     
 
Contacts      
Karen Garrity 32010C to 32150S  
 (301) 975-4818
karen.garrity@nist.gov 
Chris Meyer 32010C to 32150S
  (301) 975-4825
christopher.meyer@nist.gov 
Dawn Cross 32110C to 32147S   
 (301) 975-4822
dawn.cross@nist.gov
fax: (301) 548-0206       

Top of Page

Humidity Calibrations
     
     
Service ID # Fee, $ Description of Services
36010C 6,208 Dew-Point Hygrometers (+25 ºC to -15 ºC)
36020C 11,706 Dew-Point Hygrometers (-70 ºC to -15 ºC)
36030C At Cost Electric Hygrometers
36040C At Cost Electrolytic Hygrometers
36050C At Cost Aspirated Hygrometers
36060C At Cost Pneumatic Bridge Hygrometers
36070S At Cost Special Tests of Humidity
     
     
Contacts:    
Peter Huang
(301) 975-2621
peter.huang@nist.gov
Gregory Scace
(301) 975-2626
gregory.scace@nist.gov
fax: (301) 548-0206  