Fee Schedules (effective 1/18/07) for:
NIST
Calibration Services
|
NIST Fee Schedule
for ITS-90 Calibrations
|
| |
|
|
|
| Service ID# |
fee, $
|
|
Description of Services |
| |
|
|
|
| 33010C |
11,223
|
|
capsule SPRT (13.8 K
to 30 °C) |
| 33020C |
11,223
|
|
capsule SPRT (13.8 K
to 157 °C) |
| 33030C |
12,193
|
|
capsule SPRT (13.8 K
to 232 °C) |
| 33031C |
8,708
|
|
capsule SPRT (24.5 K
to 30 °C) |
| 33032C |
9,095
|
|
capsule SPRT (24.5 K
to 157 °C) |
| 33033C |
10,065
|
|
capsule SPRT (24.5 K
to 232 °C) |
| 33040C |
7,782
|
|
capsule SPRT (54 K to
30 °C) |
| 33050C |
8,171
|
|
capsule SPRT (54 K to
157 °C) |
| 33060S |
10,110
|
|
capsule SPRT (54 K to
232 °C) |
| 33065S |
at cost
|
|
capsule SPRT (84 K to
0.01°C) |
| 33070C |
7,600
|
|
capsule SPRT (84 K to
30 °C) |
| 33080C |
7,600
|
|
capsule SPRT (84 K to
157°C) |
| 33090C |
9,543
|
|
capsule SPRT (84 K to
232°C) |
|
33100C
|
2,891
|
|
capsule SPRT (0 °C
to 30 °C) |
| 33110C |
3,375
|
|
capsule SPRT (0 °C
to 157 °C) |
| 33120C |
5,122
|
|
capsule SPRT (0 °C
to 232 °C) |
| 33130C |
5,295
|
|
capsule SPRT (234 K
to 30 °C) |
| 33140C |
11,844
|
|
Rhodium-Iron or Platinum-Cobalt Resistance
Thermometers (0.65 K to 24.6 K) |
| 33141C |
14,564
|
|
Rhodium-Iron or Platinum-Cobalt
Resistance Thermometers (0.65 K to 83.8 K) |
33142C
|
13,393
|
|
n-Type Germanium Resistance Thermometers
(0.65 K to 24.6 K) |
| 33150C |
3,820
|
|
long stem SPRT (83 K
to 0.01 °C) |
| 33160C |
4,499
|
|
long stem SPRT (83 K
to 30 °C) |
| 33170C |
5,178
|
|
long stem SPRT (83 K
to 157 °C) |
| 33180C |
5,857
|
|
long stem SPRT (83 K
to 232 °C) |
| 33190C |
6,922
|
|
long stem SPRT (83 K
to 420 °C) |
| 33200C |
7,989
|
|
long stem SPRT (83 K
to 661 °C) |
| 33210C |
3,162
|
|
long stem SPRT (234
K to 30 °C) |
| 33220C |
4,131
|
|
long stem SPRT (234
K to 157 °C) |
| 33230C |
5,005
|
|
long stem SPRT (234
K to 232 °C) |
| 33240C |
5,975
|
|
long stem SPRT (234
K to 420 °C) |
| 33250C |
7,333
|
|
long stem SPRT (234
K to 661 °C) |
| 33260C |
1,533
|
|
long stem SPRT (0 °C
to 30 °C) |
| 33270C |
2,212
|
|
long stem SPRT (0 °C
to 157 °C) |
| 33280C |
2,890
|
|
long stem SPRT (0 °C
to 232 °C) |
| 33290C |
3,861
|
|
long stem SPRT (0 °C
to 420 °C) |
| 33300C |
5,122
|
|
long stem SPRT (0 °C
to 661 °C) |
| 33310C |
10,558
|
|
long stem SPRT (0 °C
to 962 °C) |
| 33320C |
114
|
|
additional table at
time of test |
| 33330C |
385
|
|
additional table at
later date |
| 33340C |
638
|
|
minimum charge for unsuitable
thermometer |
| 33350S |
at cost
|
|
special test of resistance
thermometer |
| 33360S |
at cost
|
|
special test of thermometric
fixed-point |
| 33370M |
23,976
|
|
long stem SPRT (83 K
to 420 °C) |
| 33380M |
26,740
|
|
long stem SPRT (83 K
to 661 °C) |
| |
|
|
|
| Contacts: |
|
>83.8
K: Greg Strouse, (301) 975-4803, gstrouse@nist.gov
>83.8
K: Mark Reeher, (301) 975-4821, mark.reeher@nist.gov
|
| <84 K: Wes Tew, (301)
975-4811, wtew@nist.gov |
| fax: (301) 548-0206 |
Top of Page
|
NIST
Fee Schedule for Industrial Thermometer Calibrations < 550 °C
|
| |
|
|
| NOTE: The minimum
number of test points per thermometer is two. Fahrenheit ranges are not
direct conversions of the Celsius ranges. |
| |
|
|
| Service ID# |
fee, $ |
Description of Services |
| |
|
|
| |
|
Liquid-in-Glass Thermometers |
| 31010C |
452/pt |
Laboratory
Thermometers (0 ºC to 150 ºC) (32 ºF to 300 ºF) |
| 31020C |
555/pt |
Laboratory
Thermometers (151 ºC to 315 ºC) (301 ºF to
600 ºF ) |
| 31030C |
555/pt |
Laboratory
Thermometers (316 ºC to 550 ºC) (601 ºF to
1022 ºF ) |
| 31040C |
555/pt |
Laboratory
Thermometers (-1 ºC to -110 ºC) (31 ºF to -166
ºF) |
| 31050C |
452/pt |
Laboratory
Thermometers (Liquid N2) (-196 ºC or -321 º
F) |
| 31100C |
at cost |
Quantity Tests
of Liquid-In-Glass Thermometers |
| |
|
|
| |
|
Resistance Thermometers |
| 31110S |
452/pt |
Special Tests
of Industrial Platinum Resistance Thermometers, Thermistor
Thermometers, Digital Thermometers and Other Types of Thermometers
(0 ºC to 150 ºC) (32 ºF to 300 ºF
) |
| 31120S |
555/pt |
Special Tests
of Industrial Platinum Resistance Thermometers, Thermistor
Thermometers, Digital Thermometers and Other Types of Thermometers
(151 ºC to 315 ºC) (301 ºF to 600 ºF
) |
| 31130S |
555/pt |
Special Tests
of Industrial Platinum Resistance Thermometers, Thermistor
Thermometers, Digital Thermometers and Other Types of Thermometers
(316 ºC to 550 ºC) (601 ºF to 1022 ºF
) |
| 31140S |
555/pt |
Special Tests
of Industrial Platinum Resistance Thermometers, Thermistor
Thermometers, Digital Thermometers and Other Types of Thermometers
(-1 ºC to -110 ºC) (31 ºF to -166 ºF ) |
| 31150S |
452/pt |
Special Tests
of Industrial Platinum Resistance Thermometers, Thermistor
Thermometers, Digital Thermometers and Other Types of Thermometers
(Liquid N2) (-196 ºC or -321 ºF) |
| |
|
|
| |
|
Special Thermometers |
| 31170S |
1,768 |
Special Tests
of Calorimetric Thermometers |
| 31180S |
1,829 |
Special Tests
of Beckmann Thermometers |
| |
|
|
| |
|
Additional Services |
| 31190S |
392 |
Additional
copy of Table from Results of 31110S-31150S at a Later Date |
| 31200S |
88 |
Preliminary
Examination of Ineligible Thermometer |
| 31250S |
88 |
Additional
Copy of Report |
| 31260S |
at cost |
Special Thermometry
Services, by Prearrangement |
| |
|
|
| Contacts: |
| Greg Strouse,
(301) 975-4803, gstrouse@nist.gov |
| Dawn Cross, (301) 975-4822,
dawn.cross@nist.gov |
| fax: (301)
548-0206 |
Top of Page
|
Thermocouples,
Thermocouple Materials, and Thermometer Indicators
|
| COMPARISON
CALIBRATIONS, TEMPERATURE MEASURED WITH THERMOCOUPLE |
| Service ID# |
Fee, $ |
TC Type |
Temp Range ºC |
Points |
Min. Length (mm) |
Temp. °C |
Expanded Uncert., k=2, °C |
| |
|
|
|
|
|
|
|
| 32010C |
1,199 |
S |
0 to 1450 |
1 ºC or 1 °F Interv. Table |
700 |
0 to 1100, 1450 |
0.3, 1.6 |
| 32020C |
1,199 |
R |
0 to 1450 |
1 ºC or 1 °F Interv. Table |
700 |
0 to 1100, 1450 |
0.3, 1.6 |
| 32030C |
1,803 |
B |
0 to 1750 |
1 ºC or 1 °F Interv. Table |
1000 |
0 to 800, 800 to 1100, 1450, 1750 |
(3 µV) 0.3, 1.6, 2.4 |
| 32031C |
1,199 |
B |
800 to 1750 |
1 ºC or 1 °F Interv. Table |
1000 |
800 to 1100, 1450, 1750 |
0.6, 1.6, 2.4 |
| 32040C |
1,199 |
E |
0 to 1000 |
4 to 15 |
700 |
0 to 1000 |
0.9 |
| 32041C |
1,199 |
J |
0 to 760 |
4 to 15 |
700 |
0 to 760 |
0.7 |
| 32042C |
1,199 |
K |
0 to 1100 |
4 to 15 |
700 |
0 to 1100 |
1 |
| 32043C |
1,199 |
N |
0 to 1100 |
4 to 15 |
700 |
0 to 1100 |
1 |
| 32044C |
1,199 |
T |
0 to 400 |
4 to 15 |
700 |
0 to 400 |
0.4 |
| 32050C |
556/pt |
Comparison calibration, two point min., per point,
for all items above
|
| 32060C |
308 |
Each additional table of results at 1 °C or
1 °F intervals, for type S, R, or B at later date
|
| 32061C |
184 |
Each additional table of results at 1 °C or
1 °F intervals, for type S, R, or B at time of test
|
| 32070C |
1,199 |
Thermocouple materials tested against Pt Thermoelectric
standard, 4 to 15 points, 700 mm min. lengths
|
| |
| CALIBRATION
AT METAL FREEZING POINTS, MINIMUM TC WIRE DIAMETER 0.4 mm,
FREEZING POINT DETERMINATION
AT Au, Ag, Al, AND Zn |
| Service ID# |
Fee, $ |
TC Type |
Temp Range ºC |
Points |
Min. Length (mm) |
Temp. °C |
Expanded Uncert., k=2, °C |
| 32090C |
3,031 |
S or B |
0 to 1450 |
1ºC or 1 °F Interv. Table and equations
to generate table |
1000 |
at freezing points 0 to 1100 1450 |
0.1 0.1 1.6 |
| 32091C |
1,076 |
Type S or T,
freezing point determination, per point, two point minimum |
| |
| CALIBRATION OF DIGITAL THERMOMETER INDICATOR
OR PORTABLE POTENTIOMETER |
| Service ID# |
Fee, $ |
|
| 32100C |
911 |
Indicator or
Potentiometer, first dial or range |
| 32101C |
507 |
Indicator or
Potentiometer, each additional dial or range |
| |
| COMPARISON CALIBRATION OF THERMOCOUPLES OR THERMOCOUPLE
MATERIALS TESTED
AGAINST Pt THERMOELECTRIC STANDARD, TEMPERATURE MEASURED WITH
SPRT, MINIMUM TC WIRE LENGTH 1.0 M, TWO POINT MINIMUM |
| Service ID# |
Fee, $ |
|
|
32110C
|
644/pt
|
Range -110 ºC to 315 ºC and Liquid
N2 (-196 ºC) or -166 º F
to 600 ºF and Liquid N2 (-321 ºF),
Expanded Uncertainty 0.4º C
|
|
32120C
|
644/pt
|
316 ºC to 550 ºC or 60 ºF
to 1022 ºF, Expanded Uncertainty 0.5 ºC
|
| |
| Table at one degree intervals for Type T thermocouple
for any of the following options: (The cost of the table will
be in addition to the calibration per point covered under
fee schedule services numbered 32110C-32120C.) |
| Service ID# |
Fee, $ |
|
|
32141C
|
540
|
Option 1: Table from -196 ºC to +300 ºC
(-321 ºF to +572 ºF), calibration points
at (-196, -110, -50, +100, +200, +300) ºC
|
|
32142C
|
540
|
Option 2: Table from -196 ºC to +100 ºC
(-321 ºF to +212 ºF), calibration points
at (-196, -110, -50, +50, +100) ºC
|
|
32143C
|
540
|
Option 3: Table from -110 ºC to +300 ºC
(-166 ºF to +572 ºF), calibration points
at (-110, -50, +100, +200, +300) ºC
|
|
32144C
|
540
|
Option 4: Table from -110 ºC to +100 ºC
(-166 ºF to +212 ºF), calibration points
at (-110, -50, +50, +100) ºC
|
|
32145C
|
540
|
Option 5: Table from 0 ºC to 300 ºC
(32 ºF to 572 ºF ), calibration points
at (+100, +200, +300) ºC
|
|
32146C
|
540
|
Option 6: Table from -110 ºC to 0 ºC
(-166 ºF to +32 º F), calibration points
at (-110, -50) ºC
|
|
32147C
|
540
|
Option 7: Table from -196 ºC to 0 ºC
(-321 ºF to +32 ºF), calibration points
at (-196, -110, -50) °C
|
|
32150S
|
At Cost
|
Special Tests of Thermocouples and Thermocouple
Materials
|
| |
| Contacts |
| Karen Garrity |
32010C to 32150S |
(301)
975-4818
|
karen.garrity@nist.gov |
| Chris Meyer |
32010C to 32150S |
(301)
975-4825
|
christopher.meyer@nist.gov |
| Dawn Cross |
32110C to 32147S |
(301)
975-4822
|
dawn.cross@nist.gov |
| fax: (301)
548-0206 |
Top of Page
| Humidity Calibrations |
| |
|
|
| |
|
|
| Service
ID # |
Fee,
$ |
Description
of Services |
| 36010C |
6,208 |
Dew-Point Hygrometers
(+25 ºC to -15 ºC) |
| 36020C |
11,706 |
Dew-Point Hygrometers
(-70 ºC to -15 ºC) |
| 36030C |
At Cost |
Electric Hygrometers |
| 36040C |
At Cost |
Electrolytic
Hygrometers |
| 36050C |
At Cost |
Aspirated Hygrometers |
| 36060C |
At Cost |
Pneumatic Bridge
Hygrometers |
| 36070S |
At Cost |
Special Tests
of Humidity |
| |
|
|
| |
|
|
| Contacts: |
|
|
| Peter Huang |
(301) 975-2621
|
peter.huang@nist.gov |
| Gregory Scace |
(301) 975-2626
|
gregory.scace@nist.gov |
| fax: (301)
548-0206 |
Top of Page
|